Soakwell Distance From the House and Boundaries

Allow at least the soakwell’s depth as a starting clearance from house footings and property boundaries. Water from a soakwell can weaken the soil that supports nearby footings and cause them to move. Your council may use the soakwell’s width or set a fixed minimum, so use its drainage rules when you mark out the position.

Published Updated

WA Soakwells

Sized to your council’s rule

We work out the soakwell volume your roof, paving and council need before we price, so the system copes with a storm.

Get a free quote

No call-out fee

WA Soakwells

Sized to your council’s rule

We work out the soakwell volume your roof, paving and council need before we price, so the system copes with a storm.

Get a free quote

No call-out fee

The Usual Distance From Footings

A soakwell that reaches 1.2 metres below ground needs at least 1.2 metres of clearance from buildings under the City of Rockingham’s soakwell rules. Measure the horizontal gap from the nearest edge of the soakwell to the house footing, the foundation that supports the wall.

Digging too close can also remove soil from beneath the footings.

Distance From Boundaries

For a preliminary layout, leave at least the soakwell’s depth between its outer edge and the property line shown on your site plan. If your neighbour’s wall is close to the boundary, allow the same building clearance you would for your own house. The layout needs to leave room for both the boundary and building clearances.

When Councils Differ

Councils use different measurements for the minimum distance between a soakwell and a building or boundary.

  • The City of Stirling’s drainage criteria call for at least 1 metre edge to edge, or more if the manufacturer specifies it. A qualified structural engineer can specify a different clearance.
  • The City of Joondalup’s residential guide recommends leaving at least the width of the soakwell, provided it is at least as wide as it is deep.
  • The City of Melville’s stormwater requirements set a minimum of 1.2 metres from footings and boundaries. If the soakwell is deeper than 1.2 metres, use its depth instead.

Tight Blocks

If a soakwell won’t fit down the side of your house, check whether the downpipes can reach a suitable spot in the front or back yard. In Melville, for example, a soakwell measuring 900 mm across its outside and 900 mm deep needs at least 3.3 metres between the house footing and the boundary. That leaves 1.2 metres of clearance on each side.

A narrower layout made from polypropylene modules can fit where a round unit is too wide. The layout still needs to meet the clearances and hold enough water for the roof and paving it drains. If there’s no spot that meets both needs, have a drainage designer check the site before you dig.