Stormwater Detention Tanks Explained
A stormwater detention tank holds runoff during heavy rain and releases it slowly to an approved discharge point. That reduces the rush of water reaching the street drain. If your approval calls for on-site detention, get the required storage volume and allowed discharge rate from the approved drainage design before ordering a tank.
Published Updated
WA Soakwells
Water where it shouldn’t be?
We install channel drains, driveway grates and stormwater pipe, and connect downpipes, so water stops before the house.
No call-out fee
On-Site Detention Defined
On-site detention (OSD) means keeping stormwater on the property temporarily so less water leaves at the height of a storm. Roofs and paving send water to drains faster than bare ground does. Detention spreads that discharge over a longer period so the downstream drains have less flow to carry at once.
A soakwell also stores runoff temporarily, then lets it seep into the surrounding soil. A detention tank drains through a controlled outlet. The approved drainage design says where the water goes and how quickly it can leave.
How a Detention Tank Works
Runoff enters the detention tank faster than the outlet lets it out during the heaviest rain. The tank holds that difference. As the rain eases, the outlet continues draining the tank and frees up storage for the next storm.
- The tank takes runoff from the connected roof and paved areas. A screen or silt trap upstream helps keep leaves and grit out of the outlet.
- The orifice is a small opening sized to control the flow. It can sit in the tank outlet or in a separate pit. In a gravity outlet, water flows faster through the same opening when the level in the tank is higher.
- The overflow gives excess water a planned route when the tank reaches its design level. The approved design shows where that water goes so it can pass clear of buildings.
Detention or Soakwells in Perth
Perth councils can accept soakwells where the site can absorb the required runoff within the property. The choice depends on the council’s rules and the ground at the site. Free-draining sand can suit soakwells. Clay or shallow groundwater can limit how much water they can disperse.
In the City of Gosnells, the stormwater drainage guidance covers housing development, including additions on individual lots. If an approved drainage strategy covers the estate, it sets the disposal method for each lot. Otherwise, soakwells may suit the lot if the ground investigation supports infiltration. The City requires at least 0.5 m between the soakwell base and the highest groundwater level or a low-permeability clay layer. If the investigation rules out soakage, the City requires sealed tanks with restricted outlets.
The City of Perth’s drainage connection guidelines put on-site retention first. Where retention is impractical, the City generally requires approved detention before a connection to its drains. For a new home, check the approved drainage plan or ask your designer to confirm whether an infiltration system can meet the site’s conditions.
Sizing and Types
The detention volume is the most water the tank needs to hold at any point during the design storm. The designer works out how much runoff arrives from the roof and paving over time and how much can leave through the outlet. The storm the council specifies and the permitted discharge rate both affect the result.
In a simplified example, 12,000 litres enter an empty tank during the busiest part of a storm and 4,000 litres leave in the same period. The tank needs room for the 8,000 litres still in it at that point. The designer checks the full storm and uses the highest stored volume, taking into account how the discharge changes as the tank fills.
An above-ground tank can fit where there is room next to the building and the inlet and outlet levels work. Buried options include precast concrete tanks and modular plastic cells wrapped in a watertight liner. If the tank goes under a car park, the design must account for the ground cover and the vehicles above it.
Before ordering, give the installer the approved working volume, outlet detail and pipe levels. The working volume is the space that fills and drains for detention. In a tank that also stores rainwater for reuse, that volume is the dedicated upper space that drains away between storms. Make sure the drawings also leave access to the tank, outlet and overflow after paving or landscaping.
Inspection and Upkeep
Keep the screen, flow-restricting outlet and overflow clear so the tank can fill and empty as designed. Follow the site’s maintenance schedule. Clear surface grates and arrange for a maintenance contractor to remove silt and check the outlet and its fittings. Silt takes up storage space, and a blocked outlet leaves less room for the next storm.
If water stays above the normal resting level longer than the design allows, have the outlet checked for blockage. Keep the approved drawings and show the property owner or site manager where the access covers and overflow are at handover.
WA Soakwells
Soakwells installed right, with a 10-year warranty
Free quotes and no call-out fee. We size the system to your roof and council rule, install it and back it for 10 years.
No call-out fee